Capacity factor
Actual electricity generation over a period divided by the amount possible from continuous operation at full power during that same period.
Actual electricity generation over a period divided by the amount possible from continuous operation at full power during that same period.
The idea
Capacity factor relates actual electricity output to the output a generating unit could produce if it ran continuously at full power over the same period. It is normally expressed as a percentage. Both the period and the capacity used in the calculation must be clear before comparing plants or technologies.
How it works
The calculation uses electricity generated as the numerator. The denominator is full rated power multiplied by the number of hours in the period. Weather, maintenance, water or fuel availability and operating decisions can affect actual output. The measure describes use of generating capacity over time rather than the momentary performance of equipment.
A hypothetical example
Consider a hypothetical plant rated at 100 that averages 50 for 24 hours. It produces 1,200 -hours. Continuous full-power operation would produce 2,400 -hours. Dividing actual by possible generation gives 50%. This is an arithmetic illustration, not an observation from the Jamaican hydro, wind or solar fleets.
A useful distinction
Capacity factor is different from efficiency, which concerns useful output relative to the energy entering a process. A very efficient plant may run infrequently. A higher capacity factor also does not by itself establish lower costs or greater value at every hour. Those judgments require information about demand, timing, investment and the wider system.